Removal
System Cover
Identify the system cover highlighted in blue.
Using a flat head or a Phillips screwdriver, rotate the lock counter clockwise.
Lift the latch till the system cover slides back.
Hold the cover on both sides, and lift the cover away from the system.
Airshroud
Internal PERC riser
Identify the internal PERC riser highlighted in blue.
Open the cable guiding latch for easy access.
Lower the plunger.
Hold the blue touch points and lift the internal PERC riser out of the system.
Turn the internal riser so that the PERC card is facing up.
Press the cable connector and disconnect the PERC cable from the backplane.
Backplane 10 x 2.5
Identify the cooling fan highlighted in blue.
Disconnect the cooling fan cable connected to the system board connector.
Unroute the Cooling fan cable
Lift the fan out holding the blue touch point.
Control panel -Right
Identify the control panel highlighted in blue
Using the blue touchpoints, slide the backplane cover back and lift to remove.
Open the latch that secures cables in routing guide.
Lift the cable latch and disconnect the control panel cable from the connector on the system board.
Unoute the control panel cable from the side wall of the system.
Remove the screws that secure the cable cover to the system.
Remove the cable cover securing the Right Control panel Cables
Remove the screw that secures the control panel to the system.
Holding the control panel assembly by its sides, remove from the system
Install
Control panel -Right
Identify the control panel location highlighted in blue
Route the control panel cable through the side wall of the system.
Align the right control panel assembly with the slot and slide into place
Connect the control panel cable to the connector on the system board and lower the cable latch to secure the cable in place.
Close the latch to secure cables in routing guide.
Install the cable cover to secure the Left Control panel cables
Install the screws that secure the cable cover to the system.
Install the screws to secure the control panel to the system.
Lower the backplace cover into the slot and slide until it snaps into place.
Backplane 10 x 2.5
Identify the cooling shroud location highlighted in blue
Align the tabs on the air shroud with the slots on the system.
Lower the air shroud into the system until it is firmly seated.
Internal PERC riser
Identify the internal PERC riser location highlighted in blue.
Connect the cable to the internal PERC card.
Holding the blue touch points, align the slot on the internal PERC riser to the guide on the system board.
Insert the internal riser card’s edge connector firmly into the system board connector until the riser is fully seated.
Lift the plunger to lock the riser in place.
Close the cable guiding latch .
Airshroud
System Cover
Identify the system cover location highlighted in blue.
Align the tabs on the system cover with the guide slots on the system.
Push the system cover latch down.
Using a flat head or Phillips screwdriver, rotate the lock clockwise.